iio: light: opt3001: add missing full-scale range value

BugLink: https://bugs.launchpad.net/bugs/2097393

commit 530688e39c644543b71bdd9cb45fdfb458a28eaa upstream.

The opt3001 driver uses predetermined full-scale range values to
determine what exponent to use for event trigger threshold values.
The problem is that one of the values specified in the datasheet is
missing from the implementation. This causes larger values to be
scaled down to an incorrect exponent, effectively reducing the
maximum settable threshold value by a factor of 2.

Add missing full-scale range array value.

Fixes: 94a9b7b180 ("iio: light: add support for TI's opt3001 light sensor")
Signed-off-by: Emil Gedenryd <emil.gedenryd@axis.com>
Cc: <Stable@vger.kernel.org>
Link: https://patch.msgid.link/20240913-add_opt3002-v2-1-69e04f840360@axis.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: Manuel Diewald <manuel.diewald@canonical.com>
Signed-off-by: Koichiro Den <koichiro.den@canonical.com>
This commit is contained in:
Emil Gedenryd
2024-09-13 11:57:02 +02:00
committed by Mehmet Basaran
parent ed6dd79f9b
commit 649a6b8d10
+4
View File
@@ -138,6 +138,10 @@ static const struct opt3001_scale opt3001_scales[] = {
.val = 20966,
.val2 = 400000,
},
{
.val = 41932,
.val2 = 800000,
},
{
.val = 83865,
.val2 = 600000,