ASoC: codecs: wsa884x: report temps to hwmon in millidegree of Celsius
[ Upstream commit d776f016d24816f15033169dcd081f077b6c10f4 ] Temperatures are reported in units of Celsius however hwmon expects values to be in millidegree of Celsius. Userspace tools observe values close to zero and report it as "Not available" or incorrect values like 0C or 1C. Add a simple conversion to fix that. Before the change: wsa884x-virtual-0 Adapter: Virtual device temp1: +0.0°C -- wsa884x-virtual-0 Adapter: Virtual device temp1: +0.0°C Also reported as N/A before first amplifier power on. After this change and initial wsa884x power on: wsa884x-virtual-0 Adapter: Virtual device temp1: +39.0°C -- wsa884x-virtual-0 Adapter: Virtual device temp1: +37.0°C Tested on sm8550 only. Cc: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Cc: Srinivas Kandagatla <srinivas.kandagatla@linaro.org> Signed-off-by: Alexey Klimov <alexey.klimov@linaro.org> Link: https://patch.msgid.link/20250221044024.1207921-1-alexey.klimov@linaro.org Signed-off-by: Mark Brown <broonie@kernel.org> Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
e1fc76b2bb
commit
f8dfd7c501
@@ -1875,7 +1875,7 @@ static int wsa884x_get_temp(struct wsa884x_priv *wsa884x, long *temp)
|
||||
* Reading temperature is possible only when Power Amplifier is
|
||||
* off. Report last cached data.
|
||||
*/
|
||||
*temp = wsa884x->temperature;
|
||||
*temp = wsa884x->temperature * 1000;
|
||||
return 0;
|
||||
}
|
||||
|
||||
@@ -1934,7 +1934,7 @@ static int wsa884x_get_temp(struct wsa884x_priv *wsa884x, long *temp)
|
||||
if ((val > WSA884X_LOW_TEMP_THRESHOLD) &&
|
||||
(val < WSA884X_HIGH_TEMP_THRESHOLD)) {
|
||||
wsa884x->temperature = val;
|
||||
*temp = val;
|
||||
*temp = val * 1000;
|
||||
ret = 0;
|
||||