UPSTREAM: regulator: pm8008: fix probe failure due to negative voltage selector
In the current design, the `pm8008_regulator_get_voltage_sel()` callback can return a negative value if the raw voltage value is read as 0 uV from the PMIC HW register. This can cause the probe to fail when the `machine_constraints_voltage()` check is called during the regulator registration flow. Fix this by using the helper `regulator_map_voltage_linear_range()` to convert the raw value to a voltage selector inside the mentioned get voltage selector function. This ensures that the value returned is always within the defined range. Bug: 450452014 Bug: 452256518 Change-Id: Ib895e3ae9107b8e2b4e36cfecea26aace6e1ee80 Signed-off-by: Kamal Wadhwa <kamal.wadhwa@oss.qualcomm.com> Message-ID: <20250823-pm8008-negitive-selector-v1-1-52b026a4b5e8@quicinc.com> Signed-off-by: Mark Brown <broonie@kernel.org> (cherry picked from commit ef3e9c91ed87f13dba877a20569f4a0accf0612c) Signed-off-by: Srinivasarao Pathipati <quic_c_spathi@quicinc.com> (cherry picked from commit a65997387f64d7071954d07fdd30a0443436103a)
This commit is contained in:
committed by
Treehugger Robot
parent
ddd07215be
commit
8c67d4274c
@@ -96,7 +96,7 @@ static int pm8008_regulator_get_voltage_sel(struct regulator_dev *rdev)
|
||||
|
||||
uV = le16_to_cpu(val) * 1000;
|
||||
|
||||
return (uV - preg->desc.min_uV) / preg->desc.uV_step;
|
||||
return regulator_map_voltage_linear_range(rdev, uV, INT_MAX);
|
||||
}
|
||||
|
||||
static const struct regulator_ops pm8008_regulator_ops = {
|
||||
|
||||
Reference in New Issue
Block a user