can: {cc770,sja1000}_isa: allow building on x86_64
The ISA variable is only defined if X86_32 is also defined. However,
these drivers are still useful and in use on at least some modern 64-bit
x86 industrial systems as well. With the correct module parameters, they
work as long as IO port communication is possible, despite their name
having ISA in them.
Fixes: a29689e60e ("net: handle HAS_IOPORT dependencies")
Signed-off-by: Thomas Mühlbacher <tmuehlbacher@posteo.net>
Link: https://patch.msgid.link/20240919174151.15473-2-tmuehlbacher@posteo.net
Cc: stable@vger.kernel.org
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
This commit is contained in:
committed by
Marc Kleine-Budde
parent
b6ec62e01a
commit
7b22846f8a
@@ -7,7 +7,7 @@ if CAN_CC770
|
||||
|
||||
config CAN_CC770_ISA
|
||||
tristate "ISA Bus based legacy CC770 driver"
|
||||
depends on ISA
|
||||
depends on HAS_IOPORT
|
||||
help
|
||||
This driver adds legacy support for CC770 and AN82527 chips
|
||||
connected to the ISA bus using I/O port, memory mapped or
|
||||
|
||||
@@ -87,7 +87,7 @@ config CAN_PLX_PCI
|
||||
|
||||
config CAN_SJA1000_ISA
|
||||
tristate "ISA Bus based legacy SJA1000 driver"
|
||||
depends on ISA
|
||||
depends on HAS_IOPORT
|
||||
help
|
||||
This driver adds legacy support for SJA1000 chips connected to
|
||||
the ISA bus using I/O port, memory mapped or indirect access.
|
||||
|
||||
Reference in New Issue
Block a user