From 8dd3491271948a337b13c3670f82730ea4ed5e69 Mon Sep 17 00:00:00 2001 From: Maxime Chevallier Date: Tue, 11 Mar 2025 08:51:19 +0900 Subject: [PATCH] rtc: ab-eoz9: don't fail temperature reads on undervoltage notification BugLink: https://bugs.launchpad.net/bugs/2101915 [ Upstream commit e0779a0dcf41a6452ac0a169cd96863feb5787c7 ] The undervoltage flags reported by the RTC are useful to know if the time and date are reliable after a reboot. Although the threshold VLOW1 indicates that the thermometer has been shutdown and time compensation is off, it doesn't mean that the temperature readout is currently impossible. As the system is running, the RTC voltage is now fully established and we can read the temperature. Fixes: 67075b63cce2 ("rtc: add AB-RTCMC-32.768kHz-EOZ9 RTC support") Signed-off-by: Maxime Chevallier Link: https://lore.kernel.org/r/20241122101031.68916-3-maxime.chevallier@bootlin.com Signed-off-by: Alexandre Belloni Signed-off-by: Sasha Levin Signed-off-by: Koichiro Den Signed-off-by: Stefan Bader --- drivers/rtc/rtc-ab-eoz9.c | 7 ------- 1 file changed, 7 deletions(-) diff --git a/drivers/rtc/rtc-ab-eoz9.c b/drivers/rtc/rtc-ab-eoz9.c index 04e1b8e93bc1..79d5ee7b818c 100644 --- a/drivers/rtc/rtc-ab-eoz9.c +++ b/drivers/rtc/rtc-ab-eoz9.c @@ -396,13 +396,6 @@ static int abeoz9z3_temp_read(struct device *dev, if (ret < 0) return ret; - if ((val & ABEOZ9_REG_CTRL_STATUS_V1F) || - (val & ABEOZ9_REG_CTRL_STATUS_V2F)) { - dev_err(dev, - "thermometer might be disabled due to low voltage\n"); - return -EINVAL; - } - switch (attr) { case hwmon_temp_input: ret = regmap_read(regmap, ABEOZ9_REG_REG_TEMP, &val);