scsi: ses: Fix wrong page error
If a SES device returns an error on a requested diagnostic page, we are currently printing an error indicating the wrong page was received. Fix this up to simply return a failure and only check the returned page when the diagnostic page buffer was populated by the device. Signed-off-by: Brian King <brking@linux.vnet.ibm.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
committed by
Martin K. Petersen
parent
b0e17a9b0d
commit
424f727b94
+1
-1
@@ -99,7 +99,7 @@ static int ses_recv_diag(struct scsi_device *sdev, int page_code,
|
||||
|
||||
ret = scsi_execute_req(sdev, cmd, DMA_FROM_DEVICE, buf, bufflen,
|
||||
NULL, SES_TIMEOUT, SES_RETRIES, NULL);
|
||||
if (unlikely(!ret))
|
||||
if (unlikely(ret))
|
||||
return ret;
|
||||
|
||||